Model HCP-E(SCI) is a Manual Call Point with integral short-circuit isolator, which is fully compatible with Hochiki’s ESP analogue addressable protocol. The unit incorporates a bi-coloured LED, which can be selected as pulsing/non-pulsing* for communications polling and is continuously lit when the HCP-E(SCI) is operated – in these two states the LED will show red. | |
The unit operates by pressing the EN54 compliant non-frangible (plastic) element and produces a high level ESP interrupt. A built in test function initiated by the control panel ensures the integrity of the device at all times and the device can be tested by insertion of a test key in the underside of the unit. Two terminal blocks are provided for easy connection to the loop wiring. |
|
Compatible with Morely DXc and Advanced MxPro 5 panels, this call point is for addressable fire alarm systems which allow engineers to give each device in the network an "address" and thus provide a much more accurate origin location in the event of a fire. For testing, a special key can be inserted into the underside of the call point and remote testing from a compatible control panel is also supported. |
More Information
SKU | B01HR56FUY |
---|---|
Weight | 1.000000 |
Networking Type | DisplayPort |
Reviews
Search FAQs
Questions & Answers
Model HCP-E(SCI) is a Manual Call Point with integral short-circuit isolator, which is fully compatible with Hochiki’s ESP analogue addressable protocol. The unit incorporates a bi-coloured LED, which can be selected as pulsing/non-pulsing* for communications polling and is continuously lit when the HCP-E(SCI) is operated – in these two states the LED will show red. | |
The unit operates by pressing the EN54 compliant non-frangible (plastic) element and produces a high level ESP interrupt. A built in test function initiated by the control panel ensures the integrity of the device at all times and the device can be tested by insertion of a test key in the underside of the unit. Two terminal blocks are provided for easy connection to the loop wiring. |
|
Compatible with Morely DXc and Advanced MxPro 5 panels, this call point is for addressable fire alarm systems which allow engineers to give each device in the network an "address" and thus provide a much more accurate origin location in the event of a fire. For testing, a special key can be inserted into the underside of the call point and remote testing from a compatible control panel is also supported. |
SKU | B01HR56FUY |
---|---|
Weight | 1.000000 |
Networking Type | DisplayPort |